{"product_id":"cutler-hammer-a302ln-3-pole-10-16a-600v-manual-motor-starter-protector","title":"Cutler-Hammer A302LN 3-Pole 10-16A 600V Manual Motor Starter Protector","description":"\n\u003cdiv style=\"font-family: Arial; font-size: 14px;\"\u003e\n\n  \u003ch2 style=\"font-size: 24px; margin: 0 0 10px 0;\"\u003e\n    Cutler-Hammer A302LN 3-Pole 10-16A 600V Manual Motor Starter Protector\n  \u003c\/h2\u003e\n\n  \u003ch3 style=\"font-size: 16px; margin: 14px 0 6px 0;\"\u003eProduct Basic Information:\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eManufacturer: Cutler-Hammer\u003c\/li\u003e\n    \u003cli\u003eCatalog number: A302LN\u003c\/li\u003e\n    \u003cli\u003eSeries: A1\u003c\/li\u003e\n\u003cli\u003eReference number: 254269\u003c\/li\u003e\n    \u003cli\u003eProduct family\/series: A302 Manual Motor Protectors\u003c\/li\u003e\n    \u003cli\u003eProduct type: Manual motor starter and protector\u003c\/li\u003e\n    \u003cli\u003eCountry of origin: Poland\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3 style=\"font-size: 16px; margin: 14px 0 6px 0;\"\u003eTechnical Specifications:\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eAdjustable thermal overload range: 10 to 16 A\u003c\/li\u003e\n    \u003cli\u003eMaximum thermal overload setting: 16 A\u003c\/li\u003e\n    \u003cli\u003eConventional thermal current rating: 25 A\u003c\/li\u003e\n    \u003cli\u003eNumber of poles: 3\u003c\/li\u003e\n    \u003cli\u003ePhase configuration: Three-phase, with compatible single-phase applications\u003c\/li\u003e\n    \u003cli\u003eRated insulation voltage: 600 VAC\u003c\/li\u003e\n    \u003cli\u003eIEC operational voltage ratings: 230, 400, 415, 500, and 690 VAC\u003c\/li\u003e\n    \u003cli\u003eRated frequency: 50\/60 Hz\u003c\/li\u003e\n    \u003cli\u003eUtilization category: AC-3\u003c\/li\u003e\n    \u003cli\u003eProtection technology: Thermal-magnetic\u003c\/li\u003e\n    \u003cli\u003eThermal overload protection: Adjustable bimetallic overload release\u003c\/li\u003e\n    \u003cli\u003eThermal overload trip class: Class 10\u003c\/li\u003e\n    \u003cli\u003eInstantaneous magnetic trip: Approximately 190 A\u003c\/li\u003e\n    \u003cli\u003eOverload trip characteristic: Approximately 125% of the selected overload setting\u003c\/li\u003e\n    \u003cli\u003eShort-circuit trip mechanism: Instantaneous magnetic release\u003c\/li\u003e\n    \u003cli\u003eSingle-phase fault sensitivity: Integrated\u003c\/li\u003e\n    \u003cli\u003eThermal overload compensation: Ambient temperature compensated\u003c\/li\u003e\n    \u003cli\u003eRated impulse withstand voltage: 8 kV\u003c\/li\u003e\n    \u003cli\u003eRated ultimate short-circuit breaking capacity at 230 VAC: 6 kA\u003c\/li\u003e\n    \u003cli\u003eRated ultimate short-circuit breaking capacity at 400 VAC: 4 kA\u003c\/li\u003e\n    \u003cli\u003eRated ultimate short-circuit breaking capacity at 415 VAC: 3.5 kA\u003c\/li\u003e\n    \u003cli\u003eRated ultimate short-circuit breaking capacity at 500 VAC: 3 kA\u003c\/li\u003e\n    \u003cli\u003eRated ultimate short-circuit breaking capacity at 690 VAC: 1 kA\u003c\/li\u003e\n    \u003cli\u003eMaximum single-phase motor rating at 115 VAC: 1 HP\u003c\/li\u003e\n    \u003cli\u003eMaximum single-phase motor rating at 200 VAC: 2 HP\u003c\/li\u003e\n    \u003cli\u003eMaximum single-phase motor rating at 230 VAC: 2 HP\u003c\/li\u003e\n    \u003cli\u003eMaximum three-phase motor rating at 200 VAC: 3 HP\u003c\/li\u003e\n    \u003cli\u003eMaximum three-phase motor rating at 230 VAC: 5 HP\u003c\/li\u003e\n    \u003cli\u003eMaximum three-phase motor rating at 460 VAC: 10 HP\u003c\/li\u003e\n    \u003cli\u003eMaximum three-phase motor rating at 575 VAC: 10 HP\u003c\/li\u003e\n    \u003cli\u003eOperating mechanism: Manual pushbutton ON\/OFF control\u003c\/li\u003e\n    \u003cli\u003eSTART control: Black pushbutton\u003c\/li\u003e\n    \u003cli\u003eSTOP control: Red pushbutton\u003c\/li\u003e\n    \u003cli\u003eOverload adjustment: Front-mounted rotary current setting dial\u003c\/li\u003e\n    \u003cli\u003eTerminal configuration: Three line terminals and three load terminals\u003c\/li\u003e\n    \u003cli\u003eLoad terminal identification: 2\/T1, 4\/T2, and 6\/T3\u003c\/li\u003e\n    \u003cli\u003eTerminal style: Recessed screw terminals with finger protection\u003c\/li\u003e\n    \u003cli\u003eMounting: 35 mm DIN rail or panel mounting with screws\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3 style=\"font-size: 16px; margin: 14px 0 6px 0;\"\u003eProduct Designed Use:\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eDesigned for manual starting, stopping, and protection of compatible industrial electric motors\u003c\/li\u003e\n    \u003cli\u003eSuitable for three-phase motor control circuits requiring adjustable thermal overload and instantaneous magnetic fault protection\u003c\/li\u003e\n    \u003cli\u003eDesigned for use in industrial motor control panels, machinery control systems, and compatible motor control centers\u003c\/li\u003e\n    \u003cli\u003eSuitable for pumps, fans, compressors, conveyors, material handling equipment, and other motor-driven machinery\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic;\"\u003e\n    COUNTRY OF ORIGIN INFORMATION IS INCLUDED WHERE AVAILABLE.\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic;\"\u003e\n    *Buyer is responsible for all customs duties, tariffs, brokerage fees, local levies, taxes, and VAT (if applicable).*\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic; font-weight: bold;\"\u003e\n    KJ CONTROLS LTD IS NOT AN AUTHORIZED DISTRIBUTOR FOR EATON \/ CUTLER-HAMMER\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic; font-weight: bold; color: red;\"\u003e\n    THE ORIGINAL MANUFACTURER'S WARRANTY DOES NOT APPLY\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic;\"\u003e\n    (51A2 - Shop 1)\n  \u003c\/p\u003e\n\n\u003c\/div\u003e\n","brand":"Cutler-Hammer","offers":[{"title":"Default Title","offer_id":68187119059223,"sku":null,"price":129.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/8879\/3879\/files\/57_52899f29-b958-4074-8c95-89ac8c02622a.jpg?v=1793642745","url":"https:\/\/kjcontracting.net\/products\/cutler-hammer-a302ln-3-pole-10-16a-600v-manual-motor-starter-protector","provider":"kjcontracting.net","version":"1.0","type":"link"}