{"product_id":"cutler-hammer-westinghouse-nd312t33w-3-pole-1200a-50ka-circuit-breaker","title":"Cutler-Hammer Westinghouse ND312T33W 3-Pole 1200A 50kA Circuit Breaker","description":"\u003cdiv style=\"font-family: Arial; font-size: 14px;\"\u003e\n\n  \u003ch2 style=\"font-size: 24px; margin: 0 0 10px 0;\"\u003e\n    Cutler-Hammer Westinghouse ND312T33W 3-Pole 1200A 50kA Circuit Breaker\n  \u003c\/h2\u003e\n\n  \u003ch3 style=\"font-size: 16px; margin: 14px 0 6px 0;\"\u003eProduct Basic Information:\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eManufacturer: Cutler-Hammer\u003c\/li\u003e\n    \u003cli\u003eLegacy brand: Westinghouse\u003c\/li\u003e\n    \u003cli\u003eCatalog number: ND312T33W\u003c\/li\u003e\n    \u003cli\u003eStyle number: 1484D02G09\u003c\/li\u003e\n    \u003cli\u003eProduct family\/series: Series C\u003c\/li\u003e\n    \u003cli\u003eFrame family: ND \/ N-Frame\u003c\/li\u003e\n    \u003cli\u003eProduct type: Electronic molded case circuit breaker\u003c\/li\u003e\n    \u003cli\u003eCountry of origin: U.S.A.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3 style=\"font-size: 16px; margin: 14px 0 6px 0;\"\u003eTechnical Specifications:\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eInstalled continuous current rating: 800 A\u003c\/li\u003e\n    \u003cli\u003eMaximum frame current rating: 1200 A\u003c\/li\u003e\n    \u003cli\u003eNumber of poles: 3\u003c\/li\u003e\n    \u003cli\u003eMaximum rated voltage: 600 VAC\u003c\/li\u003e\n    \u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n    \u003cli\u003eCurrent type: AC\u003c\/li\u003e\n    \u003cli\u003eTrip technology: Electronic\u003c\/li\u003e\n    \u003cli\u003eTrip unit: Digitrip RMS 310\u003c\/li\u003e\n    \u003cli\u003eProtection functions: LS - Long Delay and Short Delay\u003c\/li\u003e\n    \u003cli\u003eInstalled rating plug: 12NES800T\u003c\/li\u003e\n    \u003cli\u003eInstalled rating plug current: 800 A\u003c\/li\u003e\n    \u003cli\u003eShort-delay pickup range with installed 800 A plug: 1,600 to 6,400 A\u003c\/li\u003e\n    \u003cli\u003eInterrupting capacity at 240 VAC: 65 kA RMS symmetrical\u003c\/li\u003e\n    \u003cli\u003eInterrupting capacity at 480 VAC: 50 kA RMS symmetrical\u003c\/li\u003e\n    \u003cli\u003eInterrupting capacity at 600 VAC: 25 kA RMS symmetrical\u003c\/li\u003e\n    \u003cli\u003eBreaker rating: 80% rated\u003c\/li\u003e\n    \u003cli\u003eIEC utilization category: Category A\u003c\/li\u003e\n    \u003cli\u003eRated impulse withstand voltage (Uimp): 8 kV\u003c\/li\u003e\n    \u003cli\u003eIEC Icu at 240 VAC: 85 kA\u003c\/li\u003e\n    \u003cli\u003eIEC Ics at 240 VAC: 85 kA\u003c\/li\u003e\n    \u003cli\u003eIEC Icu at 380 VAC: 50 kA\u003c\/li\u003e\n    \u003cli\u003eIEC Ics at 380 VAC: 50 kA\u003c\/li\u003e\n    \u003cli\u003eIEC Icu at 415 VAC: 50 kA\u003c\/li\u003e\n    \u003cli\u003eIEC Ics at 415 VAC: 50 kA\u003c\/li\u003e\n    \u003cli\u003eIEC Icu at 690 VAC: 20 kA\u003c\/li\u003e\n    \u003cli\u003eIEC Ics at 690 VAC: 10 kA\u003c\/li\u003e\n    \u003cli\u003eCatalog configuration: Without terminals\u003c\/li\u003e\n    \u003cli\u003eCompatible fixed rating plug range: 600, 700, 800, 900, 1000 and 1200 A\u003c\/li\u003e\n    \u003cli\u003eCompatible adjustable rating plug: A12NES1200T1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3 style=\"font-size: 16px; margin: 14px 0 6px 0;\"\u003eProduct Designed Use:\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eDesigned for overcurrent and short-circuit protection in high-current industrial electrical systems\u003c\/li\u003e\n    \u003cli\u003eSuitable for switchboards, switchgear, motor control centers, distribution equipment and industrial machinery\u003c\/li\u003e\n    \u003cli\u003eSuitable for three-phase AC power distribution systems up to 600 VAC\u003c\/li\u003e\n    \u003cli\u003eElectronic LS protection provides long-delay overload and adjustable short-delay fault protection\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic;\"\u003e\n    COUNTRY OF ORIGIN INFORMATION IS INCLUDED WHERE AVAILABLE.\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic;\"\u003e\n    * Buyer is responsible for all customs duties, tariffs, brokerage fees, local levies, taxes, and VAT (if applicable).*\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic; font-weight: bold;\"\u003e\n    KJ CONTROLS LTD IS NOT AN AUTHORIZED DISTRIBUTOR FOR EATON\u003c\/p\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic;\"\u003e\n    (26C4 - Shop 2)\n  \u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Cutler-Hammer","offers":[{"title":"Default Title","offer_id":55114772185367,"sku":null,"price":4999.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/8879\/3879\/files\/57_574de78f-046f-4dac-a2fb-9233c49cc01e.jpg?v=1788465922","url":"https:\/\/kjcontracting.net\/products\/cutler-hammer-westinghouse-nd312t33w-3-pole-1200a-50ka-circuit-breaker","provider":"kjcontracting.net","version":"1.0","type":"link"}