{"product_id":"eaton-cutler-hammer-ldcb3600ft33w-3-pole-500a-100ka-circuit-breaker","title":"Eaton Cutler-Hammer LDCB3600FT33W 3-Pole 500A 100kA Circuit Breaker","description":"\u003cdiv style=\"font-family: Arial; font-size: 14px;\"\u003e\n\n  \u003ch2 style=\"font-size: 24px; margin: 0 0 10px 0;\"\u003e\n    Eaton Cutler-Hammer LDCB3600FT33W 3-Pole 500A 100kA Circuit Breaker\n  \u003c\/h2\u003e\n\n  \u003ch3 style=\"font-size: 16px; margin: 14px 0 6px 0;\"\u003eProduct Basic Information:\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eManufacturer: Eaton\u003c\/li\u003e\n    \u003cli\u003eBrand: Cutler-Hammer\u003c\/li\u003e\n    \u003cli\u003eCatalog number: LDCB3600FT33W\u003c\/li\u003e\n    \u003cli\u003eStyle number: 6613C93G69\u003c\/li\u003e\n    \u003cli\u003eProduct family\/series: Series C \/ L-Frame\u003c\/li\u003e\n    \u003cli\u003eProduct type: Current-limiting electronic molded case circuit breaker\u003c\/li\u003e\n    \u003cli\u003eInstalled trip unit: LES3600LS\u003c\/li\u003e\n    \u003cli\u003eInstalled rating plug: 6LES500T\u003c\/li\u003e\n    \u003cli\u003eCountry of origin: U.S.A.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3 style=\"font-size: 16px; margin: 14px 0 6px 0;\"\u003eTechnical Specifications:\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eInstalled continuous current rating: 500 A\u003c\/li\u003e\n    \u003cli\u003eFrame maximum current rating: 600 A\u003c\/li\u003e\n    \u003cli\u003eNumber of poles: 3\u003c\/li\u003e\n    \u003cli\u003eMaximum rated voltage: 600 VAC\u003c\/li\u003e\n    \u003cli\u003eFrequency: 50\/60 Hz\u003c\/li\u003e\n    \u003cli\u003eCurrent type: AC\u003c\/li\u003e\n    \u003cli\u003eBreaker frame: LDCB current-limiting L-frame\u003c\/li\u003e\n    \u003cli\u003eTrip technology: Electronic\u003c\/li\u003e\n    \u003cli\u003eTrip unit: Eaton Digitrip RMS 310 LES3600LS\u003c\/li\u003e\n    \u003cli\u003eProtection functions: LS - Long Delay and Short Delay\u003c\/li\u003e\n    \u003cli\u003eRating plug catalog number: 6LES500T\u003c\/li\u003e\n    \u003cli\u003eRating plug current: 500 A\u003c\/li\u003e\n    \u003cli\u003eInterrupting capacity at 240 VAC: 200 kA RMS symmetrical\u003c\/li\u003e\n    \u003cli\u003eInterrupting capacity at 480 VAC: 100 kA RMS symmetrical\u003c\/li\u003e\n    \u003cli\u003eInterrupting capacity at 600 VAC: 50 kA RMS symmetrical\u003c\/li\u003e\n    \u003cli\u003eIEC utilization category: Category A\u003c\/li\u003e\n    \u003cli\u003eRated impulse withstand voltage (Uimp): 8 kV\u003c\/li\u003e\n    \u003cli\u003eIEC ultimate breaking capacity (Icu) at 240 VAC: 200 kA\u003c\/li\u003e\n    \u003cli\u003eIEC service breaking capacity (Ics) at 240 VAC: 150 kA\u003c\/li\u003e\n    \u003cli\u003eIEC ultimate breaking capacity (Icu) at 415 VAC: 100 kA\u003c\/li\u003e\n    \u003cli\u003eIEC service breaking capacity (Ics) at 415 VAC: 75 kA\u003c\/li\u003e\n    \u003cli\u003eIEC ultimate breaking capacity (Icu) at 690 VAC: 35 kA\u003c\/li\u003e\n    \u003cli\u003eIEC service breaking capacity (Ics) at 690 VAC: 18 kA\u003c\/li\u003e\n    \u003cli\u003eSuitable for single-phase AC circuits: Yes\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3 style=\"font-size: 16px; margin: 14px 0 6px 0;\"\u003eProduct Features:\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eHeavy-duty 600 A maximum L-frame construction\u003c\/li\u003e\n    \u003cli\u003eThree-pole configuration for industrial AC power distribution\u003c\/li\u003e\n    \u003cli\u003eCurrent-limiting design for high available fault-current applications\u003c\/li\u003e\n    \u003cli\u003e100 kA interrupting capacity at 480 VAC\u003c\/li\u003e\n    \u003cli\u003e50 kA interrupting capacity at the full 600 VAC rating\u003c\/li\u003e\n    \u003cli\u003eLES3600LS Digitrip RMS 310 electronic trip unit\u003c\/li\u003e\n    \u003cli\u003eLong-delay and adjustable short-delay protection\u003c\/li\u003e\n    \u003cli\u003eShort-delay pickup adjustable from 2 to 8 times the rating-plug current\u003c\/li\u003e\n    \u003cli\u003ePush-to-trip function for breaker testing\u003c\/li\u003e\n    \u003cli\u003eStatus indication and test connection integrated into the trip unit\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3 style=\"font-size: 16px; margin: 14px 0 6px 0;\"\u003eProduct Designed Use:\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eDesigned for overcurrent and short-circuit protection in high-current industrial electrical systems\u003c\/li\u003e\n    \u003cli\u003eSuitable for switchboards, switchgear, motor control centers, distribution panels, and industrial machinery\u003c\/li\u003e\n    \u003cli\u003eCurrent-limiting construction is suitable for installations with high available fault currents\u003c\/li\u003e\n    \u003cli\u003eSuitable for three-phase AC distribution systems up to 600 VAC\u003c\/li\u003e\n    \u003cli\u003eAlso rated for appropriate single-phase AC applications\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic;\"\u003e\n    COUNTRY OF ORIGIN INFORMATION IS INCLUDED WHERE AVAILABLE.\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic;\"\u003e\n    * Buyer is responsible for all customs duties, tariffs, brokerage fees, local levies, taxes, and VAT (if applicable).*\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic; font-weight: bold;\"\u003e\n    KJ CONTROLS LTD IS NOT AN AUTHORIZED DISTRIBUTOR FOR EATON\u003c\/p\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic;\"\u003e\n    (41A4 - Upstairs Warehouse)\n  \u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":55111953285399,"sku":null,"price":7999.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/8879\/3879\/files\/57_0ecdb57c-694a-4cda-ac78-4293d556b9ba.jpg?v=1788455366","url":"https:\/\/kjcontracting.net\/products\/eaton-cutler-hammer-ldcb3600ft33w-3-pole-500a-100ka-circuit-breaker","provider":"kjcontracting.net","version":"1.0","type":"link"}