{"product_id":"startco-se-701-ground-fault-monitor-protection-relay","title":"STARTCO SE-701 Ground Fault Monitor Protection Relay","description":"\u003cdiv style=\"font-family: Arial; font-size: 14px;\"\u003e\n\n  \u003ch2 style=\"font-size: 24px; margin: 0 0 10px 0;\"\u003e\n    STARTCO SE-701 Ground Fault Monitor Protection Relay\u003c\/h2\u003e\n\n  \u003ch3 style=\"font-size: 16px; margin: 14px 0 6px 0;\"\u003eProduct Basic Information:\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eManufacturer: STARTCO Engineering Ltd.\u003c\/li\u003e\n    \u003cli\u003eModel: SE-701\u003c\/li\u003e\n    \u003cli\u003eProduct family\/series: SE-701 Series \/ PGR-5701\u003c\/li\u003e\n    \u003cli\u003eProduct type: Ground-fault monitor \/ protection relay\u003c\/li\u003e\n    \u003cli\u003eIEEE protection functions: 50G\/N and 51G\/N\u003c\/li\u003e\n    \u003cli\u003eApplication: Resistance-grounded and solidly grounded AC systems\u003c\/li\u003e\n    \u003cli\u003eCountry of origin: Canada\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3 style=\"font-size: 16px; margin: 14px 0 6px 0;\"\u003eTechnical Specifications:\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eGround-fault pickup range: 1 to 99% of CT primary rating\u003c\/li\u003e\n    \u003cli\u003ePickup adjustment resolution: 1% increments\u003c\/li\u003e\n    \u003cli\u003eMinimum pickup with compatible EFCT sensor: 50 mA\u003c\/li\u003e\n    \u003cli\u003eTrip characteristic: Definite time\u003c\/li\u003e\n    \u003cli\u003eAdjustable trip delay: 0.05 to 2.5 seconds\u003c\/li\u003e\n    \u003cli\u003eTrip time selections: 0.05, 0.10, 0.20, 0.30, 0.40, 0.50, 1.0, 1.5, 2.0, and 2.5 seconds\u003c\/li\u003e\n    \u003cli\u003eCurrent sensor inputs: 1 A, 5 A, and compatible 50 mA EFCT sensors\u003c\/li\u003e\n    \u003cli\u003eOutput relay contacts: Isolated normally open and normally closed\u003c\/li\u003e\n    \u003cli\u003eOutput contact rating: 8 A general use at 250 VAC\u003c\/li\u003e\n    \u003cli\u003eDC output contact rating: 8 A resistive at 30 VDC\u003c\/li\u003e\n    \u003cli\u003eRelay operating mode: Selectable fail-safe or non-fail-safe\u003c\/li\u003e\n    \u003cli\u003eReset mode: Selectable latching or automatic reset\u003c\/li\u003e\n    \u003cli\u003eAnalog output: 0 to 5 VDC\u003c\/li\u003e\n    \u003cli\u003eAnalog output scaling: 5 V equals 100% of CT primary rating\u003c\/li\u003e\n    \u003cli\u003eFiltering: Selectable fixed-frequency DFT or variable-frequency peak detection\u003c\/li\u003e\n    \u003cli\u003eCT loop monitoring: Supported with compatible EFCT current sensors\u003c\/li\u003e\n    \u003cli\u003eStatus indicators: Power, trip, and trip-inhibit LEDs\u003c\/li\u003e\n    \u003cli\u003eControls: Front-panel pickup adjustment, trip delay, test, and reset\u003c\/li\u003e\n    \u003cli\u003eRemote reset: Supported through external normally open momentary contact\u003c\/li\u003e\n    \u003cli\u003eTerminal conductor range: 24 to 12 AWG\u003c\/li\u003e\n    \u003cli\u003eMounting style: DIN rail or surface mount\u003c\/li\u003e\n    \u003cli\u003eOptional panel mounting: PMA-55 or PMA-60 adapter\u003c\/li\u003e\n    \u003cli\u003eDimensions: Approximately 75 mm H x 55 mm W x 113 mm D\u003c\/li\u003e\n    \u003cli\u003eApproximate shipping weight: 0.45 kg (1 lb)\u003c\/li\u003e\n    \u003cli\u003eSupply voltage: Dependent on exact SE-701 supply version\u003c\/li\u003e\n    \u003cli\u003eApprovals: UL Listed, CSA certified, and CE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3 style=\"font-size: 16px; margin: 14px 0 6px 0;\"\u003eProduct Designed Use:\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eDesigned for ground-fault protection of resistance-grounded and solidly grounded AC systems\u003c\/li\u003e\n    \u003cli\u003eSuitable for main distribution, feeder-level, and individual-load protection\u003c\/li\u003e\n    \u003cli\u003eSuitable for industrial switchgear, motor control centers, distribution equipment, and machinery\u003c\/li\u003e\n    \u003cli\u003eSuitable for systems with significant harmonic content\u003c\/li\u003e\n    \u003cli\u003eSuitable for compatible variable-frequency drive applications\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic;\"\u003e\n    COUNTRY OF ORIGIN INFORMATION IS INCLUDED WHERE AVAILABLE.\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic;\"\u003e\n    * Buyer is responsible for all customs duties, tariffs, brokerage fees, local levies, taxes, and VAT (if applicable).*\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic; font-weight: bold;\"\u003e\n    KJ CONTROLS LTD IS NOT AN AUTHORIZED DISTRIBUTOR FOR STARTCO \/ LITTELFUSE\u003c\/p\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic;\"\u003e\n    (51A2 - Shop 1)\n  \u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"STARTCO","offers":[{"title":"Default Title","offer_id":68003141845271,"sku":null,"price":289.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/8879\/3879\/files\/57_cd748daa-f615-4801-bbc3-a9ec867e98e9.jpg?v=1793041513","url":"https:\/\/kjcontracting.net\/products\/startco-se-701-ground-fault-monitor-protection-relay","provider":"kjcontracting.net","version":"1.0","type":"link"}