{"product_id":"tci-trans-coil-kdrb1l-kdr-480v-30a-20hp-line-reactor","title":"TCI Trans-Coil KDRB1L KDR 480V 30A 20HP Line Reactor","description":"\u003cdiv style=\"font-family: Arial; font-size: 14px;\"\u003e\n\n  \u003ch2 style=\"font-size: 24px; margin: 0 0 10px 0;\"\u003e\n    TCI Trans-Coil KDRB1L KDR Line Reactor 480V 30A 20HP Low-Z\n  \u003c\/h2\u003e\n\n  \u003ch3 style=\"font-size: 16px; margin: 14px 0 6px 0;\"\u003eProduct Basic Information:\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eManufacturer: TCI \/ Trans-Coil\u003c\/li\u003e\n    \u003cli\u003eCatalog number: KDRB1L\u003c\/li\u003e\n    \u003cli\u003eProduct family\/series: KDR\u003c\/li\u003e\n    \u003cli\u003eProduct type: AC line reactor \/ input line inductor\u003c\/li\u003e\n    \u003cli\u003eReactor type: Low impedance line reactor\u003c\/li\u003e\n    \u003cli\u003eCountry of origin: U.S.A.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3 style=\"font-size: 16px; margin: 14px 0 6px 0;\"\u003eTechnical Specifications:\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eProduct line: KDR\u003c\/li\u003e\n    \u003cli\u003eModel: Input reactor\u003c\/li\u003e\n    \u003cli\u003eRated voltage: 480 VAC\u003c\/li\u003e\n    \u003cli\u003eInput phase: 3 phase\u003c\/li\u003e\n    \u003cli\u003eFrequency rating: 50\/60 Hz\u003c\/li\u003e\n    \u003cli\u003eHorsepower rating: 20 HP\u003c\/li\u003e\n    \u003cli\u003eNEC motor current: 27 A\u003c\/li\u003e\n    \u003cli\u003eMaximum continuous current: 30 A\u003c\/li\u003e\n    \u003cli\u003eImpedance value: 3%\u003c\/li\u003e\n    \u003cli\u003eImpedance type: Low-Z \/ low impedance\u003c\/li\u003e\n    \u003cli\u003eEnclosure type: Open\u003c\/li\u003e\n    \u003cli\u003eTerminal type: Terminal block\u003c\/li\u003e\n    \u003cli\u003eWatts loss: 79 W\u003c\/li\u003e\n    \u003cli\u003eTemperature rise: 135 °C\u003c\/li\u003e\n    \u003cli\u003eShort-term overload rating: 200% rated current for up to 3 minutes\u003c\/li\u003e\n    \u003cli\u003eDimensions: 5 in H x 6 in W x 4 in D\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3 style=\"font-size: 16px; margin: 14px 0 6px 0;\"\u003eProduct Features:\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eTCI KDR series line reactor for variable frequency drive applications\u003c\/li\u003e\n    \u003cli\u003e480 VAC three-phase reactor configuration\u003c\/li\u003e\n    \u003cli\u003e20 HP motor application rating\u003c\/li\u003e\n    \u003cli\u003e30 A maximum continuous current capacity\u003c\/li\u003e\n    \u003cli\u003e3% low impedance design\u003c\/li\u003e\n    \u003cli\u003eOpen-style construction for panel or enclosure mounting\u003c\/li\u003e\n    \u003cli\u003eTerminal block connection design\u003c\/li\u003e\n    \u003cli\u003eDesigned to add impedance against harmonics and high-frequency disturbances\u003c\/li\u003e\n    \u003cli\u003eHelps reduce nuisance drive tripping caused by line disturbances\u003c\/li\u003e\n    \u003cli\u003eHelps reduce voltage notching and voltage distortion in drive systems\u003c\/li\u003e\n    \u003cli\u003eHelps protect connected drive components from line-side power quality issues\u003c\/li\u003e\n    \u003cli\u003eCan help improve voltage phase-to-phase imbalance in compatible installations\u003c\/li\u003e\n    \u003cli\u003eCan help extend drive system uptime in industrial motor control applications\u003c\/li\u003e\n    \u003cli\u003eUL Listed component for industrial electrical control applications\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3 style=\"font-size: 16px; margin: 14px 0 6px 0;\"\u003eProduct Designed Use:\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eDesigned for use as an input line reactor with compatible variable frequency drives\u003c\/li\u003e\n    \u003cli\u003eUsed in industrial motor control panels, machinery systems, pump systems, fan systems, conveyors, and automation equipment\u003c\/li\u003e\n    \u003cli\u003eSuitable for 480 VAC three-phase VFD applications requiring a 20 HP \/ 30 A low impedance reactor\u003c\/li\u003e\n    \u003cli\u003eUsed where line-side impedance, harmonic reduction, and drive protection are required\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic;\"\u003e\n    COUNTRY OF ORIGIN INFORMATION IS INCLUDED WHERE AVAILABLE.\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic;\"\u003e\n    * Buyer is responsible for all customs duties, tariffs, brokerage fees, local levies, taxes, and VAT (if applicable).*\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic; font-weight: bold;\"\u003e\n    KJ CONTROLS LTD IS NOT AN AUTHORIZED DISTRIBUTOR FOR TCI \/ TRANS-COIL\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic; font-weight: bold; color: red;\"\u003e\n    THE ORIGINAL MANUFACTURER'S WARRANTY DOES NOT APPLY\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic;\"\u003e\n    (5A6-2 - Upstairs Warehouse)\n  \u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"TCI","offers":[{"title":"Default Title","offer_id":53486827307287,"sku":null,"price":439.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/8879\/3879\/files\/57_627510cc-4635-4a89-94ed-429e9f0bbac9.jpg?v=1780596313","url":"https:\/\/kjcontracting.net\/products\/tci-trans-coil-kdrb1l-kdr-480v-30a-20hp-line-reactor","provider":"kjcontracting.net","version":"1.0","type":"link"}