{"product_id":"xylem-flygt-40-501098-minicas-ii-11-pin-supervision-relay-120vac","title":"Xylem Flygt 40-501098 MiniCAS II 11-Pin Supervision Relay 120VAC","description":"\u003cdiv style=\"font-family: Arial; font-size: 14px;\"\u003e\n\n  \u003ch2 style=\"font-size: 24px; margin: 0 0 10px 0;\"\u003e\n    Xylem Flygt 40-501098 MiniCAS II 11-Pin Supervision Relay 120VAC\n  \u003c\/h2\u003e\n\n  \u003ch3 style=\"font-size: 16px; margin: 14px 0 6px 0;\"\u003eProduct Basic Information:\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eManufacturer: Flygt \/ Xylem Flygt\u003c\/li\u003e\n    \u003cli\u003eCatalog number: 40-501098\u003c\/li\u003e\n    \u003cli\u003eNon-hyphenated part number: 40501098\u003c\/li\u003e\n    \u003cli\u003eProduct family\/series: MiniCAS II\u003c\/li\u003e\n    \u003cli\u003eProduct type: Pump supervision relay \/ monitoring relay\u003c\/li\u003e\n    \u003cli\u003eRelay type: Temperature and leakage monitoring relay\u003c\/li\u003e\n    \u003cli\u003eMounting style: 11-pin socket mount\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3 style=\"font-size: 16px; margin: 14px 0 6px 0;\"\u003eTechnical Specifications:\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eSeries: MiniCAS II\u003c\/li\u003e\n    \u003cli\u003ePart number: 40-501098\u003c\/li\u003e\n    \u003cli\u003eSupply voltage: 120 VAC\u003c\/li\u003e\n    \u003cli\u003eSupply voltage tolerance: -15% to +15%\u003c\/li\u003e\n    \u003cli\u003eSupply frequency: 50\/60 Hz\u003c\/li\u003e\n    \u003cli\u003ePower requirement: 5 VA\u003c\/li\u003e\n    \u003cli\u003eOperating principle: Current sensing\u003c\/li\u003e\n    \u003cli\u003eSensor output voltage: 12 VDC, +\/- 5%\u003c\/li\u003e\n    \u003cli\u003eNormal sensor current range: 3 mA to 22 mA\u003c\/li\u003e\n    \u003cli\u003eHigh temperature alarm condition: Less than 3 mA or sensor circuit interruption\u003c\/li\u003e\n    \u003cli\u003eLeakage alarm condition: Greater than 22 mA or sensor circuit short circuit\u003c\/li\u003e\n    \u003cli\u003eLeakage alarm delay: 10 seconds\u003c\/li\u003e\n    \u003cli\u003eRelay contact rating: 5 A at 250 VAC\u003c\/li\u003e\n    \u003cli\u003eTemperature alarm contact function: Changeover relay contacts\u003c\/li\u003e\n    \u003cli\u003eLeakage alarm contact function: Changeover relay contacts\u003c\/li\u003e\n    \u003cli\u003eReset type for temperature alarm: Manual reset\u003c\/li\u003e\n    \u003cli\u003eReset options: External reset push button or supply voltage interruption\u003c\/li\u003e\n    \u003cli\u003eLeakage alarm reset type: Automatic reset\u003c\/li\u003e\n    \u003cli\u003eFront indication lamps: Supply, temperature alarm, and leakage alarm\u003c\/li\u003e\n    \u003cli\u003ePump communication wiring: 2-wire sensor connection\u003c\/li\u003e\n    \u003cli\u003eSocket type: Standard 11-pin socket\u003c\/li\u003e\n    \u003cli\u003eCompatible sensor types: Thermal switches, FLS, FLS10, and CLS sensors\u003c\/li\u003e\n    \u003cli\u003eOperating temperature range: -25 to +60 °C\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3 style=\"font-size: 16px; margin: 14px 0 6px 0;\"\u003eProduct Features:\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eMonitors common submersible pump threats including high stator temperature and leakage\u003c\/li\u003e\n    \u003cli\u003eSupports thermal switch monitoring for stator overtemperature detection\u003c\/li\u003e\n    \u003cli\u003eSupports FLS leakage sensor monitoring for liquid detection in stator housing or junction box\u003c\/li\u003e\n    \u003cli\u003eSupports FLS10 leakage sensor monitoring for inspection chamber applications\u003c\/li\u003e\n    \u003cli\u003eSupports CLS water-in-oil sensor monitoring for oil chamber applications\u003c\/li\u003e\n    \u003cli\u003eThree front indication lamps for supply, temperature alarm, and leakage alarm status\u003c\/li\u003e\n    \u003cli\u003eUses two-wire communication between the pump sensor circuit and MiniCAS II relay\u003c\/li\u003e\n    \u003cli\u003eCan stop the pump or provide alarm indication depending on control wiring configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n  \u003c\/ul\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic;\"\u003e\n    COUNTRY OF ORIGIN INFORMATION IS INCLUDED WHERE AVAILABLE.\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic;\"\u003e\n    * Buyer is responsible for all customs duties, tariffs, brokerage fees, local levies, taxes, and VAT (if applicable).*\n  \u003c\/p\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic; font-weight: bold;\"\u003e\n    KJ CONTROLS LTD IS NOT AN AUTHORIZED DISTRIBUTOR FOR FLYGT \/ XYLEM FLYGT\u003c\/p\u003e\n\n  \u003cp style=\"font-size: 12px; font-style: italic;\"\u003e\n    (40A1 - Upstairs Warehouse)\n  \u003c\/p\u003e\n\n\u003c\/div\u003e","brand":"Xylem","offers":[{"title":"Default Title","offer_id":53492394328343,"sku":null,"price":699.99,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0734\/8879\/3879\/files\/57_8a431646-cdc3-4f38-a01b-c03b3cda9024.jpg?v=1780689992","url":"https:\/\/kjcontracting.net\/products\/xylem-flygt-40-501098-minicas-ii-11-pin-supervision-relay-120vac","provider":"kjcontracting.net","version":"1.0","type":"link"}